1.
Diagnostics (Basel) ; 14(8)2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38667431

RESUMO

The measurement of partial pressures of oxygen (O2) and carbon dioxide (CO2) is fundamental for evaluating a patient's conditions in clinical practice. There are many ways to retrieve O2/CO2 partial pressures and concentrations. Arterial blood gas (ABG) analysis is the gold standard technique for such a purpose, but it is invasive, intermittent, and potentially painful. Among all the alternative methods for gas monitoring, non-invasive transcutaneous O2 and CO2 monitoring has been emerging since the 1970s, being able to overcome the main drawbacks of ABG analysis. Clark and Severinghaus electrodes enabled the breakthrough for transcutaneous O2 and CO2 monitoring, respectively, and in the last twenty years, many innovations have been introduced as alternatives to overcome their limitations. This review reports the most recent solutions for transcutaneous O2 and CO2 monitoring, with a particular consideration for wearable measurement systems. Luminescence-based electronic paramagnetic resonance and photoacoustic sensors are investigated. Optical sensors appear to be the most promising, giving fast and accurate measurements without the need for frequent calibrations and being suitable for integration into wearable measurement systems.

2.
J Emerg Nurs ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38639694

RESUMO

INTRODUCTION: Noninvasive continuous blood pressure monitoring has the potential to improve patient treatment in the hospital setting. Such noninvasive devices can be applied earlier in the treatment process to empower nurses and clinicians to react more quickly to patient deterioration with the added benefit of eliminating the risks associated with invasive monitoring. However, emerging technologies must be capable of reproducing current clinical measures for medical decision making. METHODS: This study aimed to determine the usability and willingness of nurses to implement a noninvasive continuous blood pressure monitoring device. The secondary aim directly compared the systolic blood pressure, diastolic blood pressure, and mean arterial pressure values recorded by the device (VitalStream; CareTaker Medical LLC, Charlottesville, VA) with the "gold standard" brachial cuff and arterial line measures recorded in the emergency department and intensive care unit settings. RESULTS: VitalStream was similarly received by nurses in the emergency department and intensive care setting, but ultimately had greater promotion from emergency nurses. Despite some statistical similarity between measurement methodologies, all direct comparisons were found to not meet the Association for the Advancement of Medical Instrumentation 2008 and Association for the Advancement of Medical Instrumentation / European Society of Hypertension / International Organization for Standardization 2019 consensus statement criteria for acceptable blood pressure measure differences between the VitalStream and "gold standard" clinical measures. In all instances, the standard deviation of the Bland-Altman bias exceeded 8 mm Hg with less than 85% of paired differences falling within 10 mm Hg of the "gold standard." DISCUSSION: Taken together, the tested device requires additional postprocessing for medical decision making in trauma or emergent care.

3.
Healthcare (Basel) ; 12(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610175

RESUMO

Heart failure (HF) management in type 1 diabetes (T1D) is particularly challenging due to its increased prevalence and the associated risks of hospitalization and mortality, driven by diabetic cardiomyopathy. Sodium-glucose cotransporter-2 inhibitors (SGLT2-is) offer a promising avenue for treating HF, specifically the preserved ejection fraction variant most common in T1D, but their utility is hampered by the risk of euglycemic diabetic ketoacidosis (DKA). This review investigates the potential of SGLT2-is in T1D HF management alongside emergent Continuous Ketone Monitoring (CKM) technology as a means to mitigate DKA risk through a comprehensive analysis of clinical trials, observational studies, and reviews. The evidence suggests that SGLT2-is significantly reduce HF hospitalization and enhance cardiovascular outcomes. However, their application in T1D patients remains limited due to DKA concerns. CKM technology emerges as a crucial tool in this context, offering real-time monitoring of ketone levels, which enables the safe incorporation of SGLT2-is into treatment regimes by allowing for early detection and intervention in the development of ketosis. The synergy between SGLT2-is and CKM has the potential to revolutionize HF treatment in T1D, promising improved patient safety, quality of life, and reduced HF-related morbidity and mortality. Future research should aim to employ clinical trials directly assessing this integrated approach, potentially guiding new management protocols for HF in T1D.

4.
Front Physiol ; 15: 1376801, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38638276

RESUMO

In sports science, the use of wearable technology has facilitated the development of new approaches for tracking and assessing athletes' performance. This narrative review rigorously explores the evolution and contemporary state of wearable devices specifically engineered for continuously monitoring lactate levels in sweat, an essential biomarker for appraising endurance performance. Lactate threshold tests have traditionally been integral in tailoring training intensity for athletes, but these tests have relied on invasive blood tests that are impractical outside a laboratory setting. The transition to noninvasive, real-time monitoring through wearable technology introduces an innovative approach, facilitating continuous assessment without the constraints inherent in traditional methodologies. We selected 34 products from a pool of 246 articles found through a meticulous search of articles published up to January 2024 in renowned databases: PubMed, Web of Science, and ScienceDirect. We used keywords such as "sweat lactate monitoring," "continuous lactate monitoring," and "wearable devices." The findings underscore the capabilities of noninvasive sweat lactate monitoring technologies to conduct long-term assessments over a broad range of 0-100 mM, providing a safer alternative with minimal infection risks. By enabling real-time evaluations of the lactate threshold (LT) and maximal lactate steady state (MLSS), these technologies offer athletes various device options tailored to their specific sports and preferences. This review explores the mechanisms of currently available lactate monitoring technologies, focusing on electrochemical sensors that have undergone extensive research and show promise for commercialization. These sensors employ amperometric reactions to quantify lactate levels and detect changes resulting from enzymatic activities. In contrast, colorimetric sensors offer a more straightforward and user-friendly approach by displaying lactate concentrations through color alterations. Despite significant advancements, the relationship between sweat lactate and blood lactate levels remains intricate owing to various factors such as environmental conditions and the lag between exercise initiation and sweating. Furthermore, there is a marked gap in research on sweat lactate compared to blood lactate across various sports disciplines. This review highlights the need for further research to address these shortcomings and substantiate the performance of lactate sweat monitoring technologies in a broader spectrum of sports environments. The tremendous potential of these technologies to supplant invasive blood lactate tests and pioneer new avenues for athlete management and performance optimization in real-world settings heralds a promising future for integrating sports science and wearable technology.

5.
J Clin Monit Comput ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619716

RESUMO

Continuous capnography monitors patient ventilation but can be susceptible to artifact, resulting in alarm fatigue. Development of smart algorithms may facilitate accurate detection of abnormal ventilation, allowing intervention before patient deterioration. The objective of this analysis was to use machine learning (ML) to classify combined waveforms of continuous capnography and pulse oximetry as normal or abnormal. We used data collected during the observational, prospective PRODIGY trial, in which patients receiving parenteral opioids underwent continuous capnography and pulse oximetry monitoring while on the general care floor [1]. Abnormal ventilation segments in the data stream were reviewed by nine experts and inter-rater agreement was assessed. Abnormal segments were defined as the time series 60s before and 30s after an abnormal pattern was detected. Normal segments (90s continuous monitoring) were randomly sampled and filtered to discard sequences with missing values. Five ML models were trained on extracted features and optimized towards an Fß score with ß = 2. The results show a high inter-rater agreement (> 87%), allowing 7,858 sequences (2,944 abnormal) to be used for model development. Data were divided into 80% training and 20% test sequences. The XGBoost model had the highest Fß score of 0.94 (with ß = 2), showcasing an impressive recall of 0.98 against a precision of 0.83. This study presents a promising advancement in respiratory monitoring, focusing on reducing false alarms and enhancing accuracy of alarm systems. Our algorithm reliably distinguishes normal from abnormal waveforms. More research is needed to define patterns to distinguish abnormal ventilation from artifacts.

6.
Adv Mater ; : e2313612, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38574762

RESUMO

Continuous monitoring of blood pressure (BP) and multiparametric analysis of cardiac functions are crucial for the early diagnosis and therapy of cardiovascular diseases. However, existing monitoring approaches often suffer from bulky and intrusive apparatus, cumbersome testing procedures, and challenging data processing, hampering their applications in continuous monitoring. Here, a heterogeneously hierarchical piezoelectric composite is introduced for wearable continuous BP and cardiac function monitoring, overcoming the rigidity of ceramic and the insensitivity of polymer. By optimizing the hierarchical structure and components of the composite, the developed piezoelectric sensor delivers impressive performances, ensuring continuous and accurate monitoring of BP at Grade A level. Furthermore, the hemodynamic parameters are extracted from the detected signals, such as local pulse wave velocity, cardiac output, and stroke volume, all of which are in alignment with clinical results. Finally, the all-day tracking of cardiac function parameters validates the reliability and stability of the developed sensor, highlighting its potential for personalized healthcare systems, particularly in early diagnosis and timely intervention of cardiovascular disease.

7.
Front Neuroergon ; 5: 1357905, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464394

RESUMO

Introduction: Real-time physiological episode (PE) detection and management in aircrew operating high-performance aircraft (HPA) is crucial for the US Military. This paper addresses the unique challenges posed by high acceleration (G-force) in HPA aircrew and explores the potential of a novel wearable functional near-infrared spectroscopy (fNIRS) system, named NIRSense Aerie, to continuously monitor cerebral oxygenation during high G-force exposure. Methods: The NIRSense Aerie system is a flight-optimized, wearable fNIRS device designed to monitor tissue oxygenation 13-20 mm below the skin's surface. The system includes an optical frontend adhered to the forehead, an electronics module behind the earcup of aircrew helmets, and a custom adhesive for secure attachment. The fNIRS optical layout incorporates near-distance, middle-distance, and far-distance infrared emitters, a photodetector, and an accelerometer for motion measurements. Data processing involves the modified Beer-Lambert law for computing relative chromophore concentration changes. A human evaluation of the NIRSense Aerie was conducted on six subjects exposed to G-forces up to +9 Gz in an Aerospace Environmental Protection Laboratory centrifuge. fNIRS data, pulse oximetry, and electrocardiography (HR) were collected to analyze cerebral and superficial tissue oxygenation kinetics during G-loading and recovery. Results: The NIRSense Aerie successfully captured cerebral deoxygenation responses during high G-force exposure, demonstrating its potential for continuous monitoring in challenging operational environments. Pulse oximetry was compromised during G-loading, emphasizing the system's advantage in uninterrupted cerebrovascular monitoring. Significant changes in oxygenation metrics were observed across G-loading levels, with distinct responses in Deoxy-Hb and Oxy-Hb concentrations. HR increased during G-loading, reflecting physiological stress and the anti-G straining maneuver. Discussion: The NIRSense Aerie shows promise for real-time monitoring of aircrew physiological responses during high G-force exposure. Despite challenges, the system provides valuable insights into cerebral oxygenation kinetics. Future developments aim for miniaturization and optimization for enhanced aircrew comfort and wearability. This technology has potential for improving anti-G straining maneuver learning and retention through real-time cerebral oxygenation feedback during centrifuge training.

8.
ACS Nano ; 18(12): 9137-9149, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38470845

RESUMO

Point-of-care monitoring of small molecules in biofluids is crucial for clinical diagnosis and treatment. However, the inherent low degree of recognition of small molecules and the complex composition of biofluids present significant obstacles for current detection technologies. Although nanopore sensing excels in the analysis of small molecules, the direct detection of small molecules in complex biofluids remains a challenge. In this study, we present a method for sensing the small molecule drug gentamicin in whole blood based on the mechanosensitive channel of small conductance in Pseudomonas aeruginosa (PaMscS) nanopore. PaMscS can directly detect gentamicin and distinguish its main components with only a monomethyl difference. The 'molecular sieve' structure of PaMscS enables the direct measurement of gentamicin in human whole blood within 10 min. Furthermore, a continuous monitoring device constructed based on PaMscS achieved continuous monitoring of gentamicin in live rats for approximately 2.5 h without blood consumption, while the drug components can be analyzed in situ. This approach enables rapid and convenient drug monitoring with single-molecule level resolution, which can significantly lower the threshold for drug concentration monitoring and promote more efficient drug use. Moreover, this work also lays the foundation for the future development of continuous monitoring technology with single-molecule level resolution in the living body.


Assuntos
Antibacterianos , Nanoporos , Humanos , Ratos , Animais , Antibacterianos/farmacologia , Gentamicinas , Nanotecnologia , Pseudomonas aeruginosa
10.
Sensors (Basel) ; 24(4)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38400296

RESUMO

The monitoring of oxygen therapy when patients are admitted to medical and surgical wards could be important because exposure to excessive oxygen administration (EOA) may have fatal consequences. We aimed to investigate the association between EOA, monitored by wireless pulse oximeter, and nonfatal serious adverse events (SAEs) and mortality within 30 days. We included patients in the Capital Region of Copenhagen between 2017 and 2018. Patients were hospitalized due to acute exacerbation of chronic obstructive pulmonary disease (AECOPD) or after major elective abdominal cancer surgery, and all were treated with oxygen supply. Patients were divided into groups by their exposure to EOA: no exposure, exposure for 1-59 min or exposure over 60 min. The primary outcome was SAEs or mortality within 30 days. We retrieved data from 567 patients for a total of 43,833 h, of whom, 63% were not exposed to EOA, 26% had EOA for 1-59 min and 11% had EOA for ≥60 min. Nonfatal SAEs or mortality within 30 days developed in 24%, 12% and 22%, respectively, and the adjusted odds ratio for this was 0.98 (95% CI, 0.96-1.01) for every 10 min. increase in EOA, without any subgroup effects. In conclusion, we did not observe higher frequencies of nonfatal SAEs or mortality within 30 days in patients exposed to excessive oxygen administration.


Assuntos
Oxigênio , Doença Pulmonar Obstrutiva Crônica , Humanos , Oximetria , Oxigenoterapia , Hospitalização
11.
Pacing Clin Electrophysiol ; 47(4): 511-517, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38407298

RESUMO

BACKGROUND: Wearable devices based on the PPG algorithm can detect atrial fibrillation (AF) effectively. However, further investigation of its application on long-term, continuous monitoring of AF burden is warranted. METHOD: The performance of a smartwatch with continuous photoplethysmography (PPG) and PPG-based algorithms for AF burden estimation was evaluated in a prospective study enrolling AF patients admitted to Beijing Anzhen Hospital for catheter ablation from September to November 2022. A continuous Electrocardiograph patch (ECG) was used as the reference device to validate algorithm performance for AF detection in 30-s intervals. RESULTS: A total of 578669 non-overlapping 30-s intervals for PPG and ECG each from 245 eligible patients were generated. An interval-level sensitivity of PPG was 96.3% (95% CI 96.2%-96.4%), and specificity was 99.5% (95% CI 99.5%-99.6%) for the estimation of AF burden. AF burden estimation by PPG was highly correlated with AF burden calculated by ECG via Pearson correlation coefficient (R2 = 0.996) with a mean difference of -0.59 (95% limits of agreement, -7.9% to 6.7%). The subgroup study showed the robust performance of the algorithm in different subgroups, including heart rate and different hours of the day. CONCLUSION: Our results showed the smartwatch with an algorithm-based PPG monitor has good accuracy and stability in continuously monitoring AF burden compared with ECG patch monitors, indicating its potential for diagnosing and managing AF.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fotopletismografia/métodos , Estudos Prospectivos , Sensibilidade e Especificidade , Algoritmos , Eletrocardiografia/métodos
12.
Biosensors (Basel) ; 14(2)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38391980

RESUMO

Hypovolemic shock is one of the leading causes of death in the military. The current methods of assessing hypovolemia in field settings rely on a clinician assessment of vital signs, which is an unreliable assessment of hypovolemia severity. These methods often detect hypovolemia when interventional methods are ineffective. Therefore, there is a need to develop real-time sensing methods for the early detection of hypovolemia. Previously, our group developed a random-forest model that successfully estimated absolute blood-volume status (ABVS) from noninvasive wearable sensor data for a porcine model (n = 6). However, this model required normalizing ABVS data using individual baseline data, which may not be present in crisis situations where a wearable sensor might be placed on a patient by the attending clinician. We address this barrier by examining seven individual baseline-free normalization techniques. Using a feature-specific global mean from the ABVS and an external dataset for normalization demonstrated similar performance metrics compared to no normalization (normalization: R2 = 0.82 ± 0.025|0.80 ± 0.032, AUC = 0.86 ± 5.5 × 10-3|0.86 ± 0.013, RMSE = 28.30 ± 0.63%|27.68 ± 0.80%; no normalization: R2 = 0.81 ± 0.045, AUC = 0.86 ± 8.9 × 10-3, RMSE = 28.89 ± 0.84%). This demonstrates that normalization may not be required and develops a foundation for individual baseline-free ABVS prediction.


Assuntos
Hipovolemia , Sinais Vitais , Humanos , Suínos , Animais , Hipovolemia/diagnóstico , Hipovolemia/etiologia , Diagnóstico Precoce
13.
Intensive Crit Care Nurs ; 83: 103652, 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402650

RESUMO

OBJECTIVE: To investigate the correlation between body temperature and skin surface temperature in intensive care unit patients and to identify specific indicators of skin surface temperature for early fever detection. RESEARCH METHODOLOGY/DESIGN: This pilot study was a prospective, observational investigation conducted at National Cheng Kung University Hospital in Tainan, Taiwan. A total of 54 patients admitted to the Surgical Intensive Care Unit of a tertiary hospital between April and August 2020 were included. Patients utilized the wearable device HEARThremoTM to continuously monitor skin surface temperature and heart rate. Analysis of Variance was applied to identify the association of skin surface temperature with different body temperature groups. The comparison between skin surface temperature and fever over eight time intervals was studied using a generalized estimating equation. RESULTS: In 34 patients (63 %) with a fever (≥38 °C), skin surface temperature increased (P < 0.001) when body temperature increased. The maximum skin surface temperature was significantly associated with fever 180-210 min before the fever events occurred (OR: 2.22, 95 % CI: 1.30-3.80). The mean skin surface temperature was associated with fever 120-150 min before the fever events (OR: 8.70, 95 % CI: 2.08-36.36). CONCLUSIONS: Skin surface temperature can be an important early predictive sign before the onset of fever. Continuous temperature monitoring can detect fever early and initiate treatment in advance. This study serves as a preliminary exploration in this area, laying the groundwork for future comprehensive research. IMPLICATIONS FOR CLINICAL PRACTICE: Continuous monitoring of skin surface temperature empowers nurses to swiftly detect fever, transcending conventional methods. This proactive approach allows for the early identification of physiological abnormalities, facilitating the prompt initiation of further physical assessments and relevant examinations for early treatment commencement.

14.
J Pharm Sci ; 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38369018

RESUMO

As lyophilization continues to be a critical step in the manufacturing of sensitive biopharmaceuticals, challenges often arise during the scale up to commercial scale or the transfer from one manufacturing site to another. While data from the small-scale development of the lyophilization cycle is abundant it is typically much more difficult to extract important information from commercial scale cycles, due to the lack of process analytical technologies available on the commercial line. There is often a reluctance to include wireless temperature or pressure probes during GMP operations due to the additional contamination risk, and retrofitting equipment such as the TDLAS can be prohibitively expensive. Further, as products become more advanced, the cost of consuming the product or even the availability of material may limit the opportunities to run commercial scale trials. This paper presents two novel methods to garner critical cycle information to allow for the evaluation of cycle performance without the need for expensive analytical equipment, costly revalidation and line downtime. Critically, this can be achieved using commonly available temperature and capacitance probes on existing commercial scale equipment. The first method is a calorimetric method, based on quantifying the differences in heat transfer liquid temperature between the shelf inlet and shelf outlet. This change in temperature results from the on-going sublimation, an endo-thermic reaction occurring during lyophilization. The second method uses the differential pressure between the chamber and condenser resulting from the vapor flow from vial to condenser during primary drying. As stated by the authors both methods align well and provide valuable cycle characterization data.

15.
ACS Nano ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334312

RESUMO

Continuous detection of critical markers directly at the point of interest and in undiluted biological fluids represents the next fundamental step in biosensing. The goal of realizing such a platform is utterly challenging because it requires a reversible biosensor that enables the tracking of pico- to nanomolar molecular concentrations over long time spans in a compact device. Here we describe a sensing method based on plasmon-enhanced fluorescence capable of single-molecule detection of unlabeled analyte by employing biofunctionalized gold nanoparticles. The very strong plasmon-enhanced fluorescence signals allow for single-molecule sensing in unaltered biological media, while the use of low-affinity interactions ensures the continuous tracking of increasing and decreasing analyte concentrations with picomolar sensitivity. We demonstrate the use of a sandwich assay for a DNA cancer marker with a limit of detection of picomolar and a time response of 10 min. The enhanced single-molecule signals will allow for miniaturization into a small and cheap platform with multiplexing capability for application in point-of-care diagnostics, monitoring of industrial processes, and safe keeping of the environment.

16.
ACS Sens ; 9(2): 535-542, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38350235

RESUMO

Continuous health monitoring aims to reduce hospitalization and the need for constant supervision of the patients. For an outpatient monitoring device to be effective, it must meet certain criteria: it should demand minimal patient involvement, be reliable, be connected, remain stable with infrequent replacements, be cost-efficient, be compatible with humans, and ultimately be self-powered. Microneedle (MN) technology, designed for transdermal biosensing, offers a promising solution for meeting a wide range of these demands in the field of continuous health monitoring. A variety of MN platforms have been developed to facilitate this crucial function. Our focus in this Perspective is on the significant challenges linked to MN-based biosensors. These challenges include ensuring skin compatibility, the effective integration of biorecognition elements into the MN systems, and the durability concerns of these sensors in enabling extended periods of continuous monitoring. Tackling these hurdles could pave the way for more effective and reliable MN-based health monitoring solutions in the future.


Assuntos
Técnicas Biossensoriais , Agulhas , Humanos , Pele , Administração Cutânea
17.
Clin Chem Lab Med ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38253354

RESUMO

OBJECTIVES: Urea and creatinine concentrations in plasma are used to guide hemodialysis (HD) in patients with end-stage renal disease (ESRD). To support individualized HD treatment in a home situation, there is a clinical need for a non-invasive and continuous alternative to plasma for biomarker monitoring during and between cycles of HD. In this observational study, we therefore established the correlation of urea and creatinine concentrations between sweat, saliva and plasma in a cohort of ESRD patients on HD. METHODS: Forty HD patients were recruited at the Dialysis Department of the Catharina Hospital Eindhoven. Sweat and salivary urea and creatinine concentrations were analyzed at the start and at the end of one HD cycle and compared to the corresponding plasma concentrations. RESULTS: A decrease of urea concentrations during HD was observed in sweat, from 27.86 mmol/L to 12.60 mmol/L, and saliva, from 24.70 mmol/L to 5.64 mmol/L. Urea concentrations in sweat and saliva strongly correlated with the concentrations in plasma (ρ 0.92 [p<0.001] and 0.94 [p<0.001], respectively). Creatinine concentrations also decreased in sweat from 43.39 µmol/L to 19.69 µmol/L, and saliva, from 59.00 µmol/L to 13.70 µmol/L. However, for creatinine, correlation coefficients were lower than for urea for both sweat and saliva compared to plasma (ρ: 0.58 [p<0.001] and 0.77 [p<0.001], respectively). CONCLUSIONS: The results illustrate a proof of principle of urea measurements in sweat and saliva to monitor HD adequacy in a non-invasive and continuous manner. Biosensors enabling urea monitoring in sweat or saliva could fill in a clinical need to enable at-home HD for more patients and thereby decrease patient burden.

18.
BMC Cardiovasc Disord ; 24(1): 42, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218796

RESUMO

BACKGROUND: The muscle artifacts, caused by prominent muscle contractions, mimicking cardiac arrhythmias, might compromise the ECG signal quality and the implantable loop recorder memory capacity in patients with epilepsy. We developed an epileptic seizures clinical pattern-based implantable loop recorder manual activation algorithm, presenting its real-world efficacy here. METHODS: One hundred ninety-three patients (18-60 years) with drug-resistant focal epilepsy were consecutively enrolled and underwent a subcutaneous loop recorder implantation. Patients with focal onset-aware seizures and patients with focal impaired awareness seizures /bilateral tonic-clonic seizures without aura were recommended to use the activator once - just after the episode. Patients with focal impaired awareness seizures/bilateral tonic-clonic seizures with aura, the caregivers of patients experiencing status epilepticus, were advised to use the activator twice - during the aura and after the episode/ regaining consciousness. RESULTS: Six thousand four hundred ninety-four ECG traces (4826 - auto-triggered events, 1668 - person-activated events) were recorded and analyzed. The rate of true positive events in the person-activated group was statistically higher than in the autoactivation group (72.5% vs.19.4%, p < 0.0001). Person-activated false-positive events were observed in 30.5% of patients with focal impaired awareness seizures and 27.7% in patients with bilateral tonic-clonic seizures. The highest rate of false-positive events (61.5%) was detected in patients undergoing epileptic status, and the lowest rate (3.8%) - was in patients with focal onset aware seizures. The rate of false-positive events was significantly higher in patients with impaired awareness seizures without aura both in focal impaired awareness (45.5% vs. 19.3%, p < 0.0001) and bilateral tonic-clonic seizure groups (38.8% vs. 5.9%, p < 0.0001). CONCLUSIONS: Arrhythmias with varying clinical outcomes are expected in epilepsy patients and have been monitored continuously. The specified loop recorder external activation algorithm can improve the clinically relevant cardiac arrhythmia detection accuracy in epilepsy patients and the value of future studies.


Assuntos
Epilepsia Tônico-Clônica , Epilepsia , Humanos , Epilepsia Tônico-Clônica/diagnóstico , Convulsões/diagnóstico , Arritmias Cardíacas , Algoritmos , Eletrocardiografia
19.
Talanta ; 270: 125582, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38176248

RESUMO

Despite substantial developments in minimally invasive lactate monitoring microneedle electrodes, most such electrode developments have focused on either sensitivity or invasiveness while ignoring a wide range of detection, which is the most important factor in measuring the normal range of lactate in interstitial fluid (ISF). Herein, we present a polymer-based planar microneedle electrode fabrication using microelectromechanical and femtosecond laser technology for the continuous monitoring of lactate in ISF. The microneedle is functionalized with two-dimensional reduced graphene oxide (rGO) and electrochemically synthesized platinum nanoparticles (PtNPs). A particular quantity of Nafion (1.25 wt%) is applied on top of the lactate enzyme to create a diffusion-controlled membrane. Due to the combined effects of the planar structure of the microneedle, rGO, and membrane, the biosensor exhibited excellent linearity up to 10 mM lactate with a limit of detection of 2.04 µM, high sensitivity of 43.96 µA mM-1cm-2, a reaction time of 8 s and outstanding stability, selectivity, and repeatability. The feasibility of the microneedle is evaluated by using it to measure lactate concentrations in artificial ISF and human serum. The results demonstrate that the microneedle described here has great potential for use in real-time lactate monitoring for use in sports medicine and treatment.


Assuntos
Técnicas Biossensoriais , Grafite , Nanopartículas Metálicas , Humanos , Ácido Láctico/análise , Polímeros/análise , Nanopartículas Metálicas/química , Líquido Extracelular/química , Platina/química , Técnicas Biossensoriais/métodos , Eletrodos
20.
J Clin Monit Comput ; 38(1): 147-156, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37864755

RESUMO

PURPOSE: This study aimed to describe the 24-hour cycle of wearable sensor-obtained heart rate in patients with deterioration-free recovery and to compare it with patients experiencing postoperative deterioration. METHODS: A prospective observational trial was performed in patients following bariatric or major abdominal cancer surgery. A wireless accelerometer patch (Healthdot) continuously measured postoperative heart rate, both in the hospital and after discharge, for a period of 14 days. The circadian pattern, or diurnal rhythm, in the wearable sensor-obtained heart rate was described using peak, nadir and peak-nadir excursions. RESULTS: The study population consisted of 137 bariatric and 100 major abdominal cancer surgery patients. In the latter group, 39 experienced postoperative deterioration. Both surgery types showed disrupted diurnal rhythm on the first postoperative days. Thereafter, the bariatric group had significantly lower peak heart rates (days 4, 7-12, 14), lower nadir heart rates (days 3-14) and larger peak-nadir excursions (days 2, 4-14). In cancer surgery patients, significantly higher nadir (days 2-5) and peak heart rates (days 2-3) were observed prior to deterioration. CONCLUSIONS: The postoperative diurnal rhythm of heart rate is disturbed by different types of surgery. Both groups showed recovery of diurnal rhythm but in patients following cancer surgery, both peak and nadir heart rates were higher than in the bariatric surgery group. Especially nadir heart rate was identified as a potential prognostic marker for deterioration after cancer surgery.


Assuntos
Neoplasias , Dispositivos Eletrônicos Vestíveis , Humanos , Frequência Cardíaca/fisiologia , Ritmo Circadiano/fisiologia , Estudos Prospectivos